EtherNet/IP to PROFIBUS DPV1 Master Gateway
5204-DFNT-PDPMV1
Product Description
The ProLinx EtherNet/IP to PROFIBUS DPV1 Master Gateway creates a powerful connection between devices on an EtherNet/IP network and a PROFIBUS slave device. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and PROFIBUS DP Master configurable DB9F port.
The PROFIBUS DP Master protocol driver (PDPMV1) supports complete Master specifications according to IEC 61158 on either a Mono-Master or Multi-Master network. The module supports the DPV1 specification.
Product Applications
The DFNT-PDPMV1 modules are the ideal solution for the many applications where EtherNet/IP connectivity can be used to integrate a PROFIBUS DP slave device into a system. The EtherNet/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
EtherNet/IP (Explicit Messaging) Compatible Devices
Rockwell Automation equipment that supports EPIC:
-
PLC5/E rev C/N, D/E, E/D
-
SLC5/05 series A, OS503 frn4
-
1785-ENET Series A, rev D
-
Interchange V6.2
-
MicroLogix 1100/1400/ANY via 1761-NET-ENI
-
CompactLogix 1768-L43/L45 via 1768-ENBT
-
CompactLogix 1769-L32E/L35E/ANY
-
CompactLogix L23E
-
RSLinx Gateway V1.7+
-
ControlLogix 1756-ENET/ENBT/EN2T/EN2TR
Functional Specifications
Internal Database
The ProLinx module contains an internal database that consists of areas for application data, status information, and configuration information.
The internal database is shared between all ports on the module and is used as a conduit to pass information from a device on one network to one or more devices on another network.
Application Data Area
The data area is used to store and retrieve data by the protocol drivers and for data exchange between protocols. The database is used as a source for write commands to remote devices and holds data collected from the remote devices. Commands defined in the configuration file (stored in the configuration data area) control how the data is to be handled in the database.
Status Data Area
This area is used to store error codes, counters, and port status information for each port.
Configuration File
This file contains module configuration information such as port configuration, network information, and command configuration. This configuration file is downloaded to, or uploaded from, the module.
EtherNet/IP Protocol Specifications
The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware. (Implicit Messaging (I/O communications) is not supported)
|
General Protocol Information
|
|
Messaging
|
PCCC on CIP Explicit Messaging supported
|
|
Compatibility
|
Compatible devices include a wide assortment of other client/server devices such as:
- PLC5/E Rev. C/N, D/E, E/D or later
- SLC5/05 Series A, OS503 frn4 or later
- ControlLogix processor via 1756-ENET
- 1785-ENET Series A, Rev. D
- Interchange (release dependent)
- RSLinx Gateway V1.7 or later
|
|
Miscellaneous
|
125 word read and write data lengths Floating point data supported
|
EtherNet/IP Server Specifications
When in the Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers.
|
EtherNet/IP Server Specifications
|
|
Connections
|
Five (5) independent TCP server sockets permit remote clients to interact with all data contained in the module.
|
|
Data File
|
Data Table File Start - Fixed at N10 Data Table File Size - 100 or 1000 words
|
|
PCCC on CIP
Commands supported
(DF1 commands)
|
Basic Command Set
0x00 Protected Write
0x01 Unprotected Read
0x02 Protected Bit Write
0x05 Unprotected Bit Write 0x08 Unprotected Write
PLC-5 Command Set (0x0F)
0x00 WordRange Write (Binary Address)
0x01 WordRange Read (Binary Address)
0x00 WordRange Write (ASCII Address) 0x01 WordRange Read (ASCII Address)
SLC Command Set (0x0F)
0xA1 Prot Typed Read w/ 2 addr fields
0xA2 Prot Typed Read w/ 3 addr fields
0xA9 Prot Typed Write w/ 2 addr fields 0xAA Prot Typed Write w/ 3 addr fields
|
|
CIP Services Supported
|
0x4C CIP Data Table Read 0x4D CIP Data Table Write
|
EtherNet/IP Client Specifications
When configured in Client mode, the module controls the read/write data transfer between the gateway and other Ethernet/IP devices. When configured in this mode, data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware.
|
EtherNet/IP Client Specifications
|
|
General
|
One client
|
|
Command List
|
Support for 100 commands, each configurable for command, IP address, register to/from addressing and word/bit count
|
|
Polling of command list
|
User configurable polling of commands, including disabled, continuous and on change of data (write only)
|
|
PCCC on CIP
Commands Supported
(DF1 Commands)
|
Basic Command Set
0x00 Protected Write
0x01 Unprotected Read
0x02 Protected Bit Write
0x05 Unprotected Bit Write 0x08 Unprotected Write
PLC-5 Command Set (0x0F)
0x00 WordRange Write (Binary Address)
0x01 WordRange Read (Binary Address)
0x26 Read-Modify-Write (Binary Address)
0x00 WordRange Write (ASCII Address)
0x01 WordRange Read (ASCII Address) 0x26 Read-Modify-Write (ASCII Address)
SLC Command Set (0x0F)
0xA1 Prot Typed Read w/ 2 addr fields
0xA2 Prot Typed Read w/ 3 addr fields
0xA9 Prot Typed Write w/ 2 addr fields
0xAA Prot Typed Write w/ 3 addr fields 0xAB Prot Typed Write w/ Mask 3 addr fields
|
|
Status Data
|
Error codes available on an individual command basis.
|
EtherNet/IP (Explicit Messaging) Compatible Devices
List of Rockwell Automation material that support EPIC:
- PLC5/E rev C/N, D/E, E/D
- SLC5/05 series A, OS503 frn4
- 1785-ENET Series A, rev D
- Interchange V6.2
- MicroLogix 1100/1400/ANY via 1761-NET-ENI
- CompactLogix 1768-L43/L45 via 1768-ENBT
- CompactLogix 1769-L32E/L35E/ANY via 1761-NET-ENI
- RSLinx Gateway V1.7+
- ControlLogix 1756-ENET/ENBT/EN2T
ProLinx DFNT Client Counts
The following table lists the number and type of DFNT Clients and Servers available on ProLinx
gateways based on the companion protocol installed on the gateway.
|
ProLinx
Model Number / Part Number
|
Number of Connected DFNT Clients (TCP/IP)
|
Number of Unconnected DFNT Clients (UDP)
|
Number of Connected DFNT Servers ( TCP/IP)
|
|
5201-DFNT-101M
|
2
|
1
|
1
|
|
5201-DFNT-101S
|
2
|
1
|
1
|
|
5201-DFNT-103M
|
1
|
1
|
1
|
|
5201-DFNT-104S
|
2
|
1
|
1
|
|
5201-DFNT-ASCII
|
2
|
1
|
1
|
|
5201-DFNT-BACNET
|
2
|
1
|
1
|
|
5201-DFNT-BSCH
|
2
|
0
|
1
|
|
5201-DFNT-CLVM
|
2
|
0
|
1
|
|
5201-DFNT-DFCM
|
2
|
1
|
1
|
|
5201-DFNT-DH485
|
2
|
1
|
1
|
|
5201-DFNT-DNPM
|
1
|
1
|
1
|
|
5201-DFNT-DNPS
|
2
|
1
|
1
|
|
5201-DFNT-DNPSNET
|
2
|
1
|
1
|
|
5201-DFNT-EGD
|
1
|
1
|
1
|
|
5201-DFNT-GRCM
|
2
|
0
|
1
|
|
5201-DFNT-ISDA
|
2
|
0
|
1
|
|
5201-DFNT-MCM
|
2
|
1
|
1
|
|
5201-DFNT-PNPM
|
2
|
0
|
1
|
|
5201-MNETC-DFNT
|
1
|
1
|
0
|
|
5201-MNET-DFNT
|
1
|
1
|
1
|
|
5202-DFNT-ASCII4
|
2
|
1
|
1
|
|
5202-DFNT-BSCH4
|
2
|
0
|
1
|
|
5202-DFNT-CLVM4
|
2
|
0
|
1
|
|
5202-DFNT-DFCM4
|
1
|
1
|
1
|
|
5202-DFNT-GRCM4
|
2
|
0
|
1
|
|
5202-DFNT-ISDA4
|
2
|
0
|
1
|
|
5202-DFNT-MCM4
|
2
|
1
|
1
|
|
5202-DFNT-PNPM4
|
2
|
0
|
1
|
|
5204-DFNT-PDPM
|
5
|
1
|
1
|
|
5204-DFNT-PDPMV1
|
2
|
1
|
0
|
|
5205-DFNT-PDPS
|
5
|
1
|
1
|
|
5206-DFNT-DEM
|
5
|
1
|
1
|
|
5207-DFNT-HART
|
4
|
1
|
1
|
|
5208-DFNT-HART
|
4
|
1
|
1
|
|
5209-DFNT-CCLINK
|
2
|
1
|
1
|
|
5210-DFNT-RIO
|
5
|
1
|
1
|
|
5228-DFNT-HART(2)
|
4
|
1
|
1
|
|
5303-MBP-DFNT
|
2
|
1
|
1
|
PROFIBUS DP V1 Master Protocol Specifications
The module supports complete Master specifications according to IEC 61158. Acyclic parameter data can be transferred with Class 1 or Class 2 DPV1 services, allowing processors to easily communicate with slave devices supporting PROFIBUS DPV0/V1 protocol.
The ProLinx PDPMV1 PROFIBUS Master module acts as a PROFIBUS network scanner, transferring Input and Output data between PROFIBUS devices and the network.
- Master Busview configuration interface via included ProSoft Configuration Builder software (see PSW-PCB)
- Project-unique GSD file import library
- Monitoring and Modification of process data and DPV1 acyclic data
- Multi-drop on a PROFIBUS DPV1 network drop with other compatible devices
- Ability to be used with a repeater as a PROFIBUS Master with PROFIBUS PA slaves on the network
- Automatic project documentation
- Automatic Bus Parameter calculation
- Online slave diagnostics
- Supports all standardized baud rates, up to 12Mbps
- Supports extended diagnostic data (DPV1)
- Auto baud detection at all valid PROFIBUS DPV1 rates
- Multiple modules can be placed in a single rack
- CRC checksum determination of slave configuration consistency to processor
- Master Status LED Indicators for Operations, Network Drop Communication, Master Token-Hold
- FDT/DTM PROFIBUS master transport communication DTM software included (see PSW-CDTM-PDPM)
PROFIBUS Master Specifications
- Up to 125 Slaves can be connected with a repeater
- Up to 1536 cyclic bytes (768 words) input and 1536 bytes (768 words) output data
- Supports Extended Diagnostic Data
- RS-485 optically isolated PROFIBUS Interface with on board DC-DC converter
- Acyclic communications (DPV1), Read and Write
- Alarm Handling (DPV1)
- Supports Sync and Freeze commands
- Supports PROFIdrive 3.1 compliant parameter read and write operations
- Supports Multicast and Broadcast telegrams (DPV1)
PROFIBUS Master Port
- DB-9F Optically Isolated RS-485
- Ready, Run, Error and Token LED Indicators
- PROFIBUS DPV1 RS-485 interface with a 9-pin D shell female connector and isolated Opto-Couplers
Hardware Specifications
| Power Supply |
24 VDC nominal |
| |
18-32 VDC allowed |
| |
Positive, Negative, GND Terminals |
| |
2.5 mm screwdriver blade |
Current Load
|
500 mA max@ 32 VDC max |
| Operating Temperature |
-20 to 50°C |
| |
-4 to 122°F |
|
Storage Temperature |
-40 to 85°C |
| |
-40 to 185°F |
| Relative Humidity |
5% to 95% (non-condensing) |
| Dimensions |
Standard
5.20H x 2.07W x 4.52D inches
13.2cmH x 5.25cmW x 11.48cmD
Extended
5.20H x 2.73W x 4.52D inches
13.2cmH x 6.934cmW x 11.48cmD |
|
LED Indicators |
Power and Module Status |
| |
Application Status |
| |
Serial Port Activity LED |
| |
Serial Activity and Error LED Status |
| Configuration Serial Port |
DB-9M RS-232 only |
| |
No hardware handshaking |
Ethernet Port (Ethernet protocol gateways only) |
10Base-T half duplex RJ45 Connector |
| |
Link and Activity LED indicators |
| |
Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991 |
| |
Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration |
|
Application Serial Ports (Serial protocol gateways only) |
RS-232/422/485 |
| |
RS232 handshaking configurable |
| |
RS-422/485 DB-9 to Screw Terminal Adaptor |
| |
Note: The number of serial application ports depends on the module type, and the combination of protocols. |
|
Serial Port Isolation |
2500V RMS port signal isolation per UL 1577 |
| |
3000V DC min. isolation port to ground and port to logic |
|
Shipped with each unit |
Mini-DIN to DB-9M serial cables |
| |
4 ft RS-232 configuration cable |
| |
2.5mm screwdriver |
| |
CD (docs and Configuration utility) |
| |
RS-422/485 DB-9 to Screw Terminal Adaptor for each serial application port (serial protocols only) |
|
PROFIBUS Connector
|
DB-9F Standard PROFIBUS connector
|
|
PROFIBUS LED Indicators
|
Tkn - Green
|
|
|
Err - Red
|
|
|
Rdy - Green
|
|
|
Run - Green
|
Click here for dimensions diagram
Ordering Information
|
5204-DFNT-PDPMV1
|
EtherNet/IP to PROFIBUS DPV1 Master Gateway
|
To place an order, please contact your local ProSoft Technology, Inc. distributor. For a list of ProSoft distributors near you, click here.