EtherNet/IP to CC-Link Local & Intelligent Station
5209-DFNT-CCLINK
Product Description
The ProSoft Technology EtherNet/IP to CC-Link communication gateway allows Rockwell Automation control platform users to integrate CC-Link Master compatible products with existing EtherNet/IP control networks.
The CC-Link protocol driver acts as a Local or Intelligent Station, which enables easy connection to the CC-Link Master-controlled network for data transfer. Configuration options allow the gateway to occupy up to four (4) stations on the CC-Link network. Transient Messaging capability increases overall I/O data transfer capacity by more than 8,000 words. When configured as a Local Station, the gateway allows read-only viewing of the entire CC-Link Master cyclic database from all configured slave on the CC-Link network.
Product Applications
|
Features
|
Benefits
|
|
Powerful network integration
|
-
Communicate between dissimilar networks
-
A shared, 10,000-word database exchanges information from devices on both networks
-
Allows integration of EtherNet/IP-based systems onto a CC-Link Master-controlled network
|
|
EtherNet/IP
|
-
Client/Server Explicit Messaging communication supported
-
Allows up to five concurrent Server connections from multiple network Clients
-
Provides three concurrent Client connections, supporting up to 100 commands per Client
|
|
CC-Link Intelligent or Local Station
|
-
Compatible with CC-Link Version 1.10
-
Transient Message support for peer station communication adds more than 8,000 words of additional I/O data transfer capacity
-
Supports up to 4 occupied slave stations with 4 data words and 32 data bits per station
-
As a Local Station, provides a read-only list of all network slave cyclic and status data
-
CC-Link Partner Association (CLPA) Certification
|
|
Backed by ProSoft Technology
|
-
20-year history of delivering high-quality, reliable solutions designed with you in mind
-
Free, unlimited, worldwide Technical Support by phone anytime for pre-sale, set-up, or troubleshooting support help you get going sooner and stay running longer
-
Three-Year Warranty ensures reliability and protects against equipment failures
-
Free ProSoft Software tools tightly integrated with our gateway hardware...a simple and quick, total solution to help you make our gateways fit your applications
|
ProSoft Configuration Builder (PCB) provides a PC-based software configuration solution for quick and easy management of gateway configuration files, as well as viewing gateway and network diagnostics. The CC-Link Setup Guide and sample configuration provide a quick and easy example with step by step instructions on how to move data from one network to the other.
EtherNet/IP (Explicit Messaging) Compatible Devices
Rockwell Automation equipment that supports EPIC:
-
PLC5/E rev C/N, D/E, E/D
-
SLC5/05 series A, OS503 frn4
-
1785-ENET Series A, rev D
-
Interchange V6.2
-
MicroLogix 1100/1400/ANY via 1761-NET-ENI
-
CompactLogix 1768-L43/L45 via 1768-ENBT
-
CompactLogix 1769-L32E/L35E/ANY
-
CompactLogix L23E
-
RSLinx Gateway V1.7+
-
ControlLogix 1756-ENET/ENBT/EN2T/EN2TR
Functional Specifications
Internal Database
The ProLinx module contains an internal database that consists of areas for application data, status information, and configuration information.
The internal database is shared between all ports on the module and is used as a conduit to pass information from a device on one network to one or more devices on another network.
Application Data Area
The data area is used to store and retrieve data by the protocol drivers and for data exchange between protocols. The database is used as a source for write commands to remote devices and holds data collected from the remote devices. Commands defined in the configuration file (stored in the configuration data area) control how the data is to be handled in the database.
Status Data Area
This area is used to store error codes, counters, and port status information for each port.
Configuration File
This file contains module configuration information such as port configuration, network information, and command configuration. This configuration file is downloaded to, or uploaded from, the module.
EtherNet/IP Protocol Specifications
The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware. (Implicit Messaging (I/O communications) is not supported)
|
General Protocol Information
|
|
Messaging
|
PCCC on CIP Explicit Messaging supported
|
|
Compatibility
|
Compatible devices include a wide assortment of other client/server devices such as:
- PLC5/E Rev. C/N, D/E, E/D or later
- SLC5/05 Series A, OS503 frn4 or later
- ControlLogix processor via 1756-ENET
- 1785-ENET Series A, Rev. D
- Interchange (release dependent)
- RSLinx Gateway V1.7 or later
|
|
Miscellaneous
|
125 word read and write data lengths Floating point data supported
|
EtherNet/IP Server Specifications
When in the Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers.
|
EtherNet/IP Server Specifications
|
|
Connections
|
Five (5) independent TCP server sockets permit remote clients to interact with all data contained in the module.
|
|
Data File
|
Data Table File Start - Fixed at N10 Data Table File Size - 100 or 1000 words
|
|
PCCC on CIP
Commands supported
(DF1 commands)
|
Basic Command Set
0x00 Protected Write
0x01 Unprotected Read
0x02 Protected Bit Write
0x05 Unprotected Bit Write 0x08 Unprotected Write
PLC-5 Command Set (0x0F)
0x00 WordRange Write (Binary Address)
0x01 WordRange Read (Binary Address)
0x00 WordRange Write (ASCII Address) 0x01 WordRange Read (ASCII Address)
SLC Command Set (0x0F)
0xA1 Prot Typed Read w/ 2 addr fields
0xA2 Prot Typed Read w/ 3 addr fields
0xA9 Prot Typed Write w/ 2 addr fields 0xAA Prot Typed Write w/ 3 addr fields
|
|
CIP Services Supported
|
0x4C CIP Data Table Read 0x4D CIP Data Table Write
|
EtherNet/IP Client Specifications
When configured in Client mode, the module controls the read/write data transfer between the gateway and other Ethernet/IP devices. When configured in this mode, data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware.
|
EtherNet/IP Client Specifications
|
|
General
|
One client
|
|
Command List
|
Support for 100 commands, each configurable for command, IP address, register to/from addressing and word/bit count
|
|
Polling of command list
|
User configurable polling of commands, including disabled, continuous and on change of data (write only)
|
|
PCCC on CIP
Commands Supported
(DF1 Commands)
|
Basic Command Set
0x00 Protected Write
0x01 Unprotected Read
0x02 Protected Bit Write
0x05 Unprotected Bit Write 0x08 Unprotected Write
PLC-5 Command Set (0x0F)
0x00 WordRange Write (Binary Address)
0x01 WordRange Read (Binary Address)
0x26 Read-Modify-Write (Binary Address)
0x00 WordRange Write (ASCII Address)
0x01 WordRange Read (ASCII Address) 0x26 Read-Modify-Write (ASCII Address)
SLC Command Set (0x0F)
0xA1 Prot Typed Read w/ 2 addr fields
0xA2 Prot Typed Read w/ 3 addr fields
0xA9 Prot Typed Write w/ 2 addr fields
0xAA Prot Typed Write w/ 3 addr fields 0xAB Prot Typed Write w/ Mask 3 addr fields
|
|
Status Data
|
Error codes available on an individual command basis.
|
EtherNet/IP (Explicit Messaging) Compatible Devices
List of Rockwell Automation material that support EPIC:
- PLC5/E rev C/N, D/E, E/D
- SLC5/05 series A, OS503 frn4
- 1785-ENET Series A, rev D
- Interchange V6.2
- MicroLogix 1100/1400/ANY via 1761-NET-ENI
- CompactLogix 1768-L43/L45 via 1768-ENBT
- CompactLogix 1769-L32E/L35E/ANY via 1761-NET-ENI
- RSLinx Gateway V1.7+
- ControlLogix 1756-ENET/ENBT/EN2T
ProLinx DFNT Client Counts
The following table lists the number and type of DFNT Clients and Servers available on ProLinx
gateways based on the companion protocol installed on the gateway.
|
ProLinx
Model Number / Part Number
|
Number of Connected DFNT Clients (TCP/IP)
|
Number of Unconnected DFNT Clients (UDP)
|
Number of Connected DFNT Servers ( TCP/IP)
|
|
5201-DFNT-101M
|
2
|
1
|
1
|
|
5201-DFNT-101S
|
2
|
1
|
1
|
|
5201-DFNT-103M
|
1
|
1
|
1
|
|
5201-DFNT-104S
|
2
|
1
|
1
|
|
5201-DFNT-ASCII
|
2
|
1
|
1
|
|
5201-DFNT-BACNET
|
2
|
1
|
1
|
|
5201-DFNT-BSCH
|
2
|
0
|
1
|
|
5201-DFNT-CLVM
|
2
|
0
|
1
|
|
5201-DFNT-DFCM
|
2
|
1
|
1
|
|
5201-DFNT-DH485
|
2
|
1
|
1
|
|
5201-DFNT-DNPM
|
1
|
1
|
1
|
|
5201-DFNT-DNPS
|
2
|
1
|
1
|
|
5201-DFNT-DNPSNET
|
2
|
1
|
1
|
|
5201-DFNT-EGD
|
1
|
1
|
1
|
|
5201-DFNT-GRCM
|
2
|
0
|
1
|
|
5201-DFNT-ISDA
|
2
|
0
|
1
|
|
5201-DFNT-MCM
|
2
|
1
|
1
|
|
5201-DFNT-PNPM
|
2
|
0
|
1
|
|
5201-MNETC-DFNT
|
1
|
1
|
0
|
|
5201-MNET-DFNT
|
1
|
1
|
1
|
|
5202-DFNT-ASCII4
|
2
|
1
|
1
|
|
5202-DFNT-BSCH4
|
2
|
0
|
1
|
|
5202-DFNT-CLVM4
|
2
|
0
|
1
|
|
5202-DFNT-DFCM4
|
1
|
1
|
1
|
|
5202-DFNT-GRCM4
|
2
|
0
|
1
|
|
5202-DFNT-ISDA4
|
2
|
0
|
1
|
|
5202-DFNT-MCM4
|
2
|
1
|
1
|
|
5202-DFNT-PNPM4
|
2
|
0
|
1
|
|
5204-DFNT-PDPM
|
5
|
1
|
1
|
|
5204-DFNT-PDPMV1
|
2
|
1
|
0
|
|
5205-DFNT-PDPS
|
5
|
1
|
1
|
|
5206-DFNT-DEM
|
5
|
1
|
1
|
|
5207-DFNT-HART
|
4
|
1
|
1
|
|
5208-DFNT-HART
|
4
|
1
|
1
|
|
5209-DFNT-CCLINK
|
2
|
1
|
1
|
|
5210-DFNT-RIO
|
5
|
1
|
1
|
|
5228-DFNT-HART(2)
|
4
|
1
|
1
|
|
5303-MBP-DFNT
|
2
|
1
|
1
|
CC-Link Protocol Specifications
CC-Link (Control & Communication Link) is an open-standard-based communication protocol that enables easy connection to Mitsubishi and other Master PLCs.
- CC-Link is one of the dominant protocols used in Asia and is rapidly gaining acceptance worldwide.
- The ProLinx CC-Link interface is a slave (Local Station or Intelligent Device), which can be connected to a CC-Link Master that controls data transfer.
- The gateway is a stand-alone, DIN-rail-mounted solution that provides one CC-Link network port with TE-CON7 4P connector and an Ethernet port with RJ45 connector
CC-Link Functional Specifications
CC-Link technology is based on an Application Specific Integrated Circuit (ASIC) designed and provided by Mitsubishi Electric Automation. Each CC-Link station transfers 4 words and 32 bits of I/O data to and from the Master station. The CCLINK gateway can occupy up to 4 consecutive stations on the CC-Link network increasing it's I/O data transfer capacity.
|
Maximum Number of Occupied Stations
|
4 stations, consecutive addresses
|
|
Maximum Number of Devices per Network
|
26-64 Devices depending on Local and Slave Stations configured
|
|
Device Types Supported
|
Intelligent Device and Local Station
|
|
CC-Link Version supported
|
CC-Link Version 1.10 cyclic data transmission
|
|
Message handling
|
Cyclic Messages and Transient Messages
|
|
Cyclic Data Capacity
|
24 input data words and 24 output data words. Up to 4 slave stations supporting 4 words/32 bits per slave
|
|
Additional I/O Data Transfer Capacity
|
Transient Messaging extends I/O data transfer capacity by more than 8,000 additional words
|
|
Transient Message Commands
|
System Information, Memory Access Information, RUN, STOP, Line Test, Memory Read, and Memory Write commands
|
|
Communication speed
|
10 Mbps, 5 Mbps, 2.5 Mbps, 625 kbps, 156 kbps
|
|
Transmission path format
|
Bus format (EIA RS485 conformance)
|
|
Transmission format
|
HDLC conformance
|
|
Error control system
|
CRC (X16+X12+X5+1)
|
Hardware Specifications
|
Specification
|
Description
|
|
Power Supply
|
24 VDC nominal
18 to 32 VDC allowed
Positive, Negative, and Ground terminals 2.5 mm screwdriver blade-sized terminals
|
|
Current Load
|
500 mA max@ 32 VDC max
|
|
Operating Temperature
|
If in compliance with Relative Humidity -20 to 50°C (-4 to 122°F)
If not in compliance with Relative Humidity 0 to 50°C (32 to 122°F)
|
|
Storage Temperature
|
-40 to 85°C (-40 to 185°F)
|
|
Relative Humidity
|
5% to 95% (non-condensing)
|
|
Dimensions
|
Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD)
Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
|
|
General LED Indicators
|
Power and General Status
Application Status
Serial Port Activity LED Serial Activity and Error LED Status
|
|
CC-Link LED Indicators
|
Run (Network Status)
L Run (Data Link Execution)
L Err (Data Link Comm Error)
SD (Sending Data LED)
RD (Receiving Data LED) ERR (Switch Setting Error)
|
|
Configuration Serial Port
|
DB-9M RS-232 only No hardware handshaking
|
|
Ethernet Port
|
RJ45 Connector, 10Mbit, half-duplex only
Link and Activity LED indicators
Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration
|
|
CC-Link Interface
|
|
Pin
|
Description
|
|
DA
|
Data Communication line A
|
|
DB
|
Data Communication line B
|
|
DG
|
Digital Ground
|
|
SLD
|
Shield
|
|
FG
|
Frame Ground
|
|
|
Shipped with Each Unit
|
Mini-DIN to DB-9M serial cable
4 ft RS-232 configuration cable
2.5mm screwdriver
CD (docs and Configuration utility) CC-Link to Terminal Block connector
|
Click here for dimensions diagram
Conformance Testing
Conformance testing through the CC-Link partner Association (CLPA) ensures that the gateway meets the performance specifications required to become CC-Link certified.
Ordering Information
|
5209-DFNT-CCLINK
|
EtherNet/IP to CC-Link Local & Intelligent Station Gateway
|
To place an order, please contact your local ProSoft Technology, Inc. distributor. For a list of ProSoft distributors near you, click here.