ProSoft Technology, Inc.
Home > Products > for Schneider Electric > PTQ-AFC
Printable Page
 

Search | Clear


Gas & Liquid Flow Computer for Quantum

PTQ-AFC

The ProTalk Liquid & Gas Flow Computer Module is a Quantum backplane compatible module that allows Quantum processors to easily support flow applications performing measurement of hydrocarbon gases or liquids using AGA 3, 7, 8 and API 2540 measurement standards.

The module calculates flow rates, accumulated volumes, accumulated mass and accumulated energy (heating value). The calculation results are transferred back to the Processor memory for use in the application ladder program or for transfer back to a SCADA host.

The PTQ-AFC Flow Computer product has been approved by Industry Canada - Measurement for complying with Provisional Specifications and Procedures for the approval of Correction Devices and Linearization Functions Incorporated in Meters and Flow Computers.

Features and Benefits

Certified for Custody Transfer

  • Gas measurement is accurate to the degree that it is Industry Canada Certified for custody transfer
  • Assurance to users the flow computer's values can be used in the transfer of ownership applications

Licensed Backplane Technology

  • Manufactured under license from Schneider Electric
  • High-speed data transfer between PTQ module and Quantum processor

Automatic Flow Computer

  • 16 meter runs with four streams per run
  • Monitor each meter run (flow rates, accumulator values and other calculation results). All alarm data is displayed on the screen
  • Download and view the archives and events
  • Audit scan shows the process input variables and calculation results as "snapshots," allowing verification of the calculations
  • Access Modbus Slave data (130,000 registers) and Virtual Modbus Slave data (20,000 registers)
  • Remap Modbus data to optimize the data polling

Includes AFC Manager Configuration Software

  • Configure, monitor, archive and view status from your desktop PC
  • Modbus Master port can send Modbus commands to connected devices
  • Precise configuration of meter types, streams, fluids and gases, component analysis

Backed by ProSoft Technology

  • 20-year history of delivering high-quality, reliable solutions designed with you in mind
  • Free, unlimited, worldwide Technical Support by phone anytime for pre-sale, set-up, or troubleshooting support help you get going sooner and stay running longer
  • Three-Year Warranty ensures reliability and protects against equipment failures

Configuration

The AFC Manager is an easy-to-use Windows 98/NT/2000/XP based configuration, reporting, and monitoring tool provided with the AFC modules. Project configurations may be uploaded, downloaded and saved to the PC under user selectable file names.

General Specifications

  • Single Slot - Quantum backplane compatible
  • The module is recognized as an Options module and has access to PLC memory for data transfer
  • Configuration data is stored in non-volatile memory in the ProTalk module
  • Up to six modules can be placed in a rack
  • Local rack - The module must be placed in the same rack as processor
  • Compatible with all common Quantum programming packages, including Concept (version 2.6 or higher), Unity Pro (version 2.2 or higher), ProWORX (version 2.20 or later), andModSoft.
  • Quantum data types supported: 0x, 1x, 3x, 4x
  • High speed data transfer across backplane provides quick data update times

AFC

The AFC module operates as a powerful flow computer module, augmenting the operation of the Quantum processor by providing a dedicated and accurate set of flow calculations, the results of which are easily available to process monitoring and control applications developed on the Quantum platform.

The module is highly-configurable (see PSW-AFC), allowing each of the meter runs to be individually set up to meet the specific requirements of an application.

Configurable options

  • Gas analysis concentrations for any or all 21 components
  • Physical data for all meter runs including orifice and pipe diameters, selection of type of taps and tap location
  • Reference pressure, temperature and local atmospheric conditions
  • Default process and operating parameters including DP threshold for flow cutoff
  • Metric or imperial units
  • User selectable units for totalizers and flow rates on a per channel basis
  • Resettable and/or non-resettable totalizers for every meter channel
  • Process I/O: analog inputs (pressure, temperature, diff pressure) from analog modules and pulse inputs from pulse/frequency input modules in Quantum I/O rack
  • Number of meter channels: 16 differential (AGA3) or linear (AGA7) Gas; MPMS 12.2 Liquid
  • Number of streams per meter channel: 4 streams
  • Calculation methods: AGA3-1992, AGA 7, AGA8-1992 (detail characterization method), API MPMS Ch12.2 API 2540
  • Meter scan time under 1 second for all 16 channels
  • Product measurement: hydrocarbon gases and liquids
  • Data archiving: For each meter run, hourly for two days (48 records) and daily for one month (35 records) under default configuration, with optional extended archives up to 1440 hourly (60 days) and 1440 daily. Archive size and contents are fully configurable. All archived data is available in the onboard Modbus memory.
  • Event log report for all security sensitive configuration data (for example, orifice diameter) are date and time stamped and mapped to the local Modbus memory map. This data can be imported into any spreadsheet program and saved to disk or printed as hard copy

Modbus interface

  • The two Modbus slave ports allow the unit to be used as a SCADA interface and to broaden access to the AFC module's data table
  • Either port may be configured for RTU or ASCII Modbus mode
  • Modbus table may be re-mapped for user assigned contiguous register polling from a SCADA master (up to 20,000 registers)
  • Port 3 can be configured as a Modbus Master port to poll data from a remote chromatograph device

Functional Specifications

Data Exchange

Seamless data exchange between processor and Flow Computer with backplane compatibility

  • Supports 16 meter runs with 4 streams per meter run for the measurement of hydrocarbon gases and liquids using currently accepted industry measurement standards
  • Measurement standards supported: AGA 3, 7, 8 and API 2540
  • Calculates flow rates, accumulated volumes, accumulated mass and accumulated energy
  • Calculation results are transferred back to the processor memory or to a SCADA host
  • User configurable allowing each of the meter runs to be individually set up to meet the specific requirements of an application

Archiving

Data archiving feature provides 35 regular daily, 48 regular hourly archives or a total of 1,440 daily and hourly extended archives per meter. Event logging feature provides storage up to 1999 events station-wide.

  • Supports data archiving and event logging
  • Two Modbus slave ports allow the unit to be used as a SCADA interface and to broaden access to the flow computer's data table
  • Port 3 can be configured as a Modbus Master port to poll data from a remote chromatograph device

Hardware Specifications

Backplane Current Load

1100 mA maximum @ 5 Vdc ± 5%

Operating Temperature

0°C to 60°C (32°F to 140°F)

Storage Temperature

-40°C to 85°C (-40°F to 185°F)

Relative Humidity

5 to 95% (without condensation)

Vibration

Sine vibration 4 to100 Hz in each of the three orthogonal axes

Shock

30g, 11 mSec. in each of the three orthogonal axes

Dimensions (HxWxD), Approx.

250 x 103.85 x 40.34 mm
9.84 x 4.09 x 1.59 in

LED Indicators

Module Status
Backplane Transfer Status
Serial Port Activity LED
Serial Activity and Error LED Status

Configuration Serial Port
(PRT1)

DB-9M PC Compatible
RS-232 only
No hardware handshaking

Application Serial Ports

PRT2, PRT3
DB-9M PC Compatible
RS-232/422/485 jumper selectable
RS-422/485 screw termination included
RS-232 handshaking configurable
500V Optical isolation from backplane

Ordering Information

PTQ-AFC Gas & Liquid Flow Computer for Quantum
   
To place an order, please contact your local ProSoft Technology, Inc. distributor. For a list of ProSoft distributors near you, click here.

 

Distributors:
Place your order by email to orders@prosoft-technology.com:, fax to +1 661-716-5101.

Sales and Support:

Asia Pacific
+603.7724.2080
asiapc@prosoft-technology.com
Europe/Middle East/Africa
+33 (0)5.34.36.87.20
europe@prosoft-technology.com
Latin America
Office: +1 281.298.9109
Mobile: +1-281-830-8946
latinam@prosoft-technology.com
North America
+1 661.716.5100
Fax: +1 661.716.5101
info@prosoft-technology.com

AFC Version 2.05 Update Notice

If your module measures liquids, please read this notice before upgrading from version 2.04 (or earlier) to 2.05 (or later).

For compliance with new measurement standards, the AFC version 2.05 has introduced several new liquid product groups. In particular, the two non-refined liquid product groups of version 2.04, which covered the entire density range of crudes and NGLs, have each been split into two separate product groups, one for the higher density range of crudes and the other for the lower density range of NGLs. If your module has meter channels configured for either "Crude, NGL" or "Oil-water emulsion", you should decide before upgrading the firmware the new product group (light or heavy) to which each such channel should be assigned. This assignment will be performed during the upgrade process and will preserve all other configuration and historical records including accumulator values and archives, in contrast to changing a product group after the upgrade which resets the meter configuration and erases all historical records. Meter channels configured for "Gas" or "Refined products" are not affected.

AFC Manager exhibits the same behavior when converting a project between versions 2.04 (or earlier) and 2.05 (or later).

The criterion for assigning the new product group depends on the density units and the Default Reference Density, as detailed in the following tables:

Density Units = kg/m3

Version 2.04 Product Group

Default Reference Density

Version 2.05 Product Group

Crude, NGL

= 0 OR >= 610.0

Crude oils, JP4

Crude, NGL

> 0 AND < 610.0

NGLs, LPGs

Oil Water Emulsion

= 0 OR >= 610.0

Oil-water emulsion (Crd)

Oil Water Emulsion

> 0 AND < 610.0

Oil-water emulsion (NGL)

Density Units = Rd/60

Version 2.04 Product Group

Default Reference Density

Version 2.05 Product Group

Crude, NGL

= 0 OR >= 0.6100

Crude oils, JP4

Crude, NGL

> 0 AND < 0.6100

NGLs, LPGs

Oil Water Emulsion

= 0 OR >= 0.6100

Oil-water emulsion (Crd)

Oil Water Emulsion

> 0 AND < 0.6100

Oil-water emulsion (NGL)

Due to roundoff error of numeric conversions, a Relative Density very close to the cutoff value of 0.6100 may cause the module to assign the new product group opposite to the one that was intended. Before upgrading, change the Default Reference Density to a number significantly different from 0.6100, such as 0.6110 (to target Crude) or 0.6090 (to target NGLs). You may change it back to the correct value after the upgrade

Density Units = API Gravity

Version 2.04 Product Group

Default Reference Density

Version 2.05 Product Group

Crude, NGL

= 0 OR <= 100.0

Crude oils, JP4

Crude, NGL

> 0 AND > 100.0

NGLs, LPGs

Oil Water Emulsion

= 0 OR <= 100.0

Oil-water emulsion (Crd)

Oil Water Emulsion

> 0 AND > 100.0

Oil-water emulsion (NGL)

 

Home : Products : Support : Distributors : Services : News/Events : Contact : ProSoft Tested