ProSoft Technology, Inc.
Home > Products > for Rockwell Automation > Protocol > FieldServer
Printable Page
 

Search | Clear


FieldServer

ProSoft Technology is now the exclusive provider of SlotServer Communication Modules manufactured by FieldServer for use in Rockwell Automation ControlLogix systems. The SlotServer modules provide communication for a number of Building Automation Systems and Fire Alarm Control Panel protocols previously not available for ControlLogix.


PS56-BAS-xxx

The SlotServer ControlLogix BAS Communications Interface allows an Allen Bradley ControlLogix platform to pass data between a ControlLogix CPU and a variety of Building Automation System protocol communications networks.

Physically configured to plug into a standard ControlLogix rack, the SlotServer Module is configured for the 1756 platform using standard RSLogix message block reads to allow for efficient transfer of large blocks of data. Specific configuration data is contained in the Configuration CSV file downloaded to the module.

Comes with the standard two-year FieldServer warranty.

PS56-FIR-xxx

The SlotServer ControlLogix FIR Communications Interface allows an Allen Bradley ControlLogix platform to pass data between a ControlLogix CPU and a variety of Fire Alarm Control Panel (FACP) protocol communications networks.

Physically configured to plug into a standard ControlLogix rack, the SlotServer Module is configured for the 1756 platform using standard RSLogix message block reads to allow for efficient transfer of large blocks of data. Specific configuration data is contained in the Configuration CSV file downloaded to the module.

SlotServer provides serial and Ethernet ports to enable ControlLogix interface to any of the FACP protocols available in the FieldServer driver library including Simplex, Notifier, EST (GE) and more,

Comes with the standard two-year FieldServer warranty

PS56-BAS-019

The SlotServer ControlLogix Metasys N2 by JCI Communications Interface allows an Allen Bradley ControlLogix platform to pass data between a ControlLogix CPU and Johnson Controls Metasys N2 networks. The Metasys N2 SlotServer can be configured as a Metasys Slave or Master enabling exchange of information between Metasys Master devices such as NCM, N-30, NAE or NIE) or Metasys Slave devices such as UNT, VMA, DX9100, VAV or AHU.

Physically configured to plug into a standard ControlLogix rack, the SlotServer Module is configured for the 1756 platform using standard RSLogix message block reads to allow for efficient transfer of large blocks of data. Specific configuration data is contained in the Configuration CSV file downloaded to the module.

SlotServer is a flexible communications module that can be configured to communicate to a wide range of protocols found in the extensive FieldServer Technologies library of protocols. The SlotServer is recognized as an input/output module by ControlLogix and has access to processor memory for data transfer between processor and module.

Comes with the standard two-year FieldServer warranty

PS56-LON-000

Part Number

Protocol Version

Part Number

Protocol Version

PS56-LON-000

LonWorks for Generic SNVTs

PS56-LON-001

LonWorks for Configurable SNVTs

The SlotServer LonWorks Open Interface allows an Allen Bradley ControlLogix platform to pass data between a ControlLogix CPU and a standard LonWorks communications network. The SlotServer Module provides a standard generic profile in LonWorks that allows most of the more common Standard Network Variable Types (SNVT’s) to be bound to the SlotServer for data transfer.

Physically configured to plug into a standard ControlLogix rack, the SlotServer Module is configured using standard RSLogix message block reads to allow for efficient transfer of large blocks of data.

SlotServer provides serial and Ethernet ports to enable ControlLogix interface to any of the many protocols available in the FieldServer driver library including BACnet, JCI Metasys, and a wide range of proprietary and legacy protocols used in the building automation, fire alarm panels and process control industries.

Comes with the standard two-year FieldServer warranty.

PS56-PRO-407

The AB_CSP driver implements the Allen Bradley Ethernet protocol commonly referred to as the CSP, using PCCC message structures. The AB_CSP driver allows the SlotServer to transfer data to and from devices over AB_CSP Ethernet protocol. The SlotServer can emulate either a Server or Client.

Comes with the standard two-year FieldServer warranty.

PS56-BAS-40x, PS56-BAS-073, PS56-BAS-016

The SlotServer ControlLogix BACnet Communication Interfaces allow an Allen Bradley ControlLogix platform to pass data between a ControlLogix PAC and BACnet devices and networks. The BACnet SlotServer can be configured as a BACnet slave or Master enabling exchange of information between BACnet Master devices such as Trane BCU, Alerton Controllers, etc) or BACnet slave devices such as VSD, lighting controls, AC controls, etc.

Physically configured to plug into a standard ControlLogix rack, the SlotServer Module is configured for the 1756 platform using standard RSLogix message block reads to allow for efficient transfer of large blocks of data. Specific configuration data is contained in the Configuration CSV file downloaded to the module.

SlotServer is a flexible communications module that can be configured to communicate to a wide range of protocols found in the extensive FieldServer Technologies library of protocols. The SlotServer is recognized as an input/output module by ControlLogix and has access to processor memory for data transfer between processor and module.