DF1 Full-Half Duplex Communication Module (Master/Slave)
MVI46-DFCM
The MVI46 DF1 Master/Slave Communication Module is an SLC backplane compatible module that allows Rockwell Automation SLC I/O compatible processors to interface easily with DF1 protocol compatible devices and hosts. Devices commonly supporting the protocol include Rockwell Automation PLCs and power monitoring equipment, as well as several other third party devices in the marketplace.
Features
The MVI46-DFCM Master/Slave Communications module allows Rockwell Automation SLC I/O compatible processors to interface easily with other DF1 protocol compatible devices. Compatible devices include not only Rockwell Automation PLCs (which all support the DF1 protocol) but also a wide assortment of end devices.
The MVI46-DFCM module has two Application Serial ports supporting the DF1 protocol, with each port user-configurable to act as a master or as a slave. Data transfer between the module and the SLC processor is asynchronous to the DF1 network, with the module's internal database being used to exchange data between the processor and the DF1 network.
General Specifications
- Single Slot - 1746 backplane compatible (Local or extended I/O rack only. Remote rack not supported)
- The module is recognized as an Input/Output module and has access to processor memory for data transfer between processor and module using M0/M1 files
- Ladder Logic is used for data transfer between module and processor
- Configuration data obtained through user-defined ladder. Sample ladder file included
Applications
The MVI46-DFCM module is the ideal solution for many applications where DF1 protocol connectivity must be added to an SLC platform. Applications using the MVI46-DFCM module can be found in many industrial sectors and in the following applications:
- Foreign device data concentrator
- SCADA system pipelines and offshore
- Platforms food processing
- Mining
- Pulp and paper
Functional Specifications
DF1 ports
- Full and half duplex modes supported
- CRC and BCC error checking
- Full hardware handshaking control
- Memory usage is completely user configurable, supporting the storage and transfer of up to 5000 registers to/from the control processor
- Up to 125 word read and write command lengths supported
- Floating point data movement supported
DF1 Master Protocol Specifications
The ports on the DF1 module can be individually configured as Master ports. When configured in master mode, the DFCM module is capable of reading and writing data to remote DF1 devices, enabling the SLC platform to act as a SCADA sub-master.
- Command List: Up to 100 commands per Master port, each fully-configurable for function, slave address, register to/from addressing and word/byte count
- Status Data: Error codes available on an individual command basis. In addition, a slave status list is maintained per active master port.
- Polling of Command List: User-configurable polling of commands, including disabled, continuous, and on change of data (write only)
DF1 Slave Protocol Specifications
The module accepts DF1 commands from an attached DF1 master unit. When in slave mode, the module can accept DF1 commands from a master to read/write data stored in the module's internal registers. This data can be derived from other DF1 slave devices on the network through a master port or from the processor and is easily transferred to the processor's data registers.
Tested Hardware Connections
Several hardware connections have been tested by ProSoft Technology or have been customer field tested. To our knowledge, the following physical connections have been successful:
- RA Panel view (Full Duplex point-point, DFCM as slave)
- RA Processors (Full/Half duplex, DFCM as either master or slave)
- RA Power Monitors (485 Half-Duplex DFCM as Master)
Hardware Specifications
|
Application Serial ports (P1, P2)
|
|
|
|
Full hardware handshaking control, providing radio, modem, and multi-drop support
|
|
Software configurable communication parameter
|
Baud rate: 110 to 115,200 baud depending on protocol
Parity: None, Odd or Even
Data Bits: 5, 6, 7, or 8
Stop Bits: 1 or 2
RTS On/Off Delay: 0 to 65535 ms RS-232 handshaking configurable
|
|
App Ports (P1, P2)
|
RJ45 (DB-9M with supplied cable)
RS-232, 485, and 422 (jumper selectable) 500V optical isolation from backplane
|
|
CFG Port
|
RJ45 (DB-9M with supplied cable) RS-232 only
|
|
Shipped with unit
|
RJ45 to DB-9M adapter cable and 6-foot RS-232 configuration cable for the debug port
|
|
Specification
|
Description
|
|
Backplane Current Load
|
800 ma @ 5V (from backplane)
|
|
Operating Temperature
|
0 to 60°C (32 to 140°F)
|
|
Storage Temperature
|
-40 to 85°C (-40 to 185°F)
|
|
Shock
|
30g operational, 50g non-operational
|
|
Relative Humidity
|
5 to 95% (non-condensing)
|
|
Vibration
|
5 g from 10150 Hz
|
|
Processor
|
Compatible with Rockwell Automation SLC 5/02 M0/M1 capable processors or newer.
|
|
LED indicators
|
Module status, Backplane transfer status, Application status, Serial activity and error LED status
|
Ordering Information
| MVI46-DFCM |
DF1 Full-Half Duplex Communication Module (Master/Slave) |
| |
|
| To place an order, please contact your local ProSoft Technology, Inc. distributor. For a list of ProSoft distributors near you, click here. |
Distributors:
Place your order by email to orders@prosoft-technology.com:, fax to +1 661-716-5101.
Sales and Support:
|