ProSoft Technology, Inc.
Home > Products > for Rockwell Automation > Platform > ControlLogix > MVI56-MDA4
Printable Page
 

Search | Clear


MDA Scientific CM4 Master Module

MVI56-MDA4

The MVI56 MDA Scientific CM4 Gas Analyzer Master Module allows Rockwell Automation ControlLogix processors to interface easily as a host with MDA Scientific CM4 gas monitoring hardware (See MVI56-MDA16 for a System 16 solution).

Features and Benefits

The MVI56-MDA4 module acts as an input/output module between the CM4 network and the Rockwell Automation backplane. The data transfer from the ControlLogix processor is asynchronous from the actions on the CM4 network. A 5000-word register space in the module is used to exchange data between the processor and the CM4 network.

General Specifications

  • Single Slot - 1756 backplane compatible
  • The module is recognized as an Input/Output module and has access to processor memory for data transfer between processor and module
  • Ladder Logic is used for data transfer between module and processor. Sample ladder file included.
  • Configuration data obtained from configuration text file downloaded to module. Sample configuration file included
  • Local or remote rack

Applications

This application is useful for any industry producing, using, or exposed to toxic or corrosive gases, where interfacing the MDA4 Gas Analyzer with a ControlLogix processor is required.

Functional Specifications

  • Support for the storage and transfer of up to 5000 registers to/from the ControlLogix processor's data files
  • Two CM4 master ports.
  • Configurable parameters include:
    • Baud Rate 110 to 115,200
    • Parity None, Odd and Even
    • Data Bits 5 to 8
    • Stop Bits 1 or 2
    • RTS On and Off Timing 0 to 65535 milliseconds
    • Use of CTS Modem Line Yes or No
    • Response Timeout 0 to 65535 milliseconds
    • Number of Slaves 1 to 10
    • Reduced Data Structure Y/N
    • Protocol Version 1 or 2
    • Polling Delay 0 to 65535 milliseconds.

A port configured as a virtual CM4 master device on the MVI56-MDA4 module will actively issue CM4 commands to other nodes on the CM4 network. Four read and five write commands are supported.

The MDA-4 product includes the following standard features:

  • Two fully configurable serial ports, each capable of supporting the CM4 Master functionality
  • Supports up to 10 CM4 units per serial port, 10 total per module
  • Support movement of binary, integer, ASCII, and floating point data types
  • Memory mapping will be pre-defined in the module to ease implementation in the ladder program
  • RS-485 connection from each port directly to the CM4 units
  • Software configuration (From processor ladder logic)
    • Slave Addr: 0 to 31
    • Command: Select command to be executed
  • Supported CM4 command codes:
    • Read Commands
    • 0x30 Get System Information
    • 0x31 Get Unit Status
    • 0x36 Get Alarm History
    • 0x37 Get Current Point Status
    • Write Commands
    • 0x51 Reset Fault or Alarm
    • 0x52 Set Key-Code
    • 0x53 Lock Keyboard
    • 0x60 End Point Lock-On
    • 0x61 Start Point Lock-On
  • Operating Mode returned to ladder processor
  • Error Codes returned to the ladder processor

Hardware Specifications

Specification

Description

Backplane Current Load

800 mA @ 5 V

Operating Temperature

0 to 60°C (32 to 140°F)

Storage Temperature

-40 to 85°C (-40 to 185°F)

Shock:

30g Operational
50g non-operational
Vibration: 5 g from 10 to 150 Hz

Relative Humidity

5 to 95% (non-condensing)

LED Indicators:

Module Status
Backplane Transfer Status
Application Status
Serial Activity

Application Serial ports
(P1, P2)

 
 

Full hardware handshaking control, providing radio, modem, and multi-drop support

Software configurable communication parameter

Baud rate: 110 to 115,200 baud depending on protocol
Parity: None, Odd or Even
Data Bits: 5, 6, 7, or 8
Stop Bits: 1 or 2
RTS On/Off Delay: 0 to 65535 ms
RS-232 handshaking configurable

App Ports (P1, P2)

RJ45 (DB-9M with supplied cable)
RS-232, 485, and 422 (jumper selectable)
500V optical isolation from backplane

CFG Port

RJ45 (DB-9M with supplied cable)
RS-232 only

Shipped with unit

RJ45 to DB-9M adapter cable and 6-foot RS-232 configuration cable for the debug port

Ordering Information

MVI56-MDA4 MDA Scientific CM4 Master Module
   
To place an order, please contact your local ProSoft Technology, Inc. distributor. For a list of ProSoft distributors near you, click here.

 

Distributors:
Place your order by email to orders@prosoft-technology.com:, fax to +1 661-716-5101.

Sales and Support:

Asia Pacific
+603.7724.2080
asiapc@prosoft-technology.com
Europe
+33 (0)5.34.36.87.20
europe@prosoft-technology.com
Latin America
Office: +1 281.298.9109
Mobile: +1-281-830-8946
latinam@prosoft-technology.com
North America
+1 661.716.5100
Fax: +1 661.716.5101
info@prosoft-technology.com

 

Related Information

ProSoft Configuration Builder

Image Gallery



Home : Products : Support : Distributors : Services : News/Events : Contact Us : ProSoft Tested