ProSoft Technology, Inc.
Home > Products > for Rockwell Automation > Platform > ControlLogix > MVI56-104S
Printable Page
 

Search | Clear


IEC 60870-5-104 Server Communication Module

MVI56-104S

The MVI56 IEC 60870-5-104 Server Communication Module allows ControlLogix backplane I/O compatible processors to interface easily with IEC 60870-5-104 protocol-compatible hosts.

Features and Benefits

The MVI56-104S module acts as an input/output module between the IEC 60870-5-104 Ethernet network and the Rockwell Automation backplane. The data transfer from the ControlLogix processor is asynchronous from the actions on the network. A 4000-word register space in the module exchanges data between the processor and the Ethernet network.

General Specifications

  • Single Slot - 1756 backplane compatible
  • The module is recognized as an Input/Output module and has access to processor memory for data transfer between processor and module
  • Ladder Logic is used for data transfer between module and processor. Sample ladder file included.
  • Configuration data obtained from configuration text file downloaded to module. Sample configuration file included
  • Local or remote rack

Applications

The MVI56-104S module has been designed to address the application where a device using the IEC 60870-5-104 protocol needs to communication with the Rockwell Automation processor. As such, the IEC server module can be used as a gateway in many SCADA installations in industries such as:

  • Power
  • Petrochemical
  • Water treatment
  • Oil and gas production

Functional Specifications

The MVI56-104S module accepts data read/write commands from a master/client on the network. In addition, the module can be configured to generate unsolicited messages in either a spontaneous or cyclic fashion.

The module has 4000 words of user defined internal register space that are accessible to the protocol driver and to the ControlLogix processor memory. Any of the supported database types can be individually located (within the total database size limit of 4000 words) and each database point is mapped within the module and can be assigned to one or more Groups. The supported database point types are:

Database Type

Description

M_SP_NA

Monitored single-point database

M_DP_NA

Monitored dual-point database

M_ST_NA

Monitored step-point database

M_ME_NA

Monitored normalized-point database

M_ME_NB

Monitored scaled-point database

M_ME_NC

Monitored short-float point database

M_IT_NA

Monitored integrated total database

C_SC_NA

Command single-point database

C_DC_NA

Command dual-point database

C_RC_NA

Command step-point database

C_SE_NA

Command normalized-point database

C_SE_NB

Command scaled-point database

C_SE_NC

Command short-float point database

IEC 60870-5-104 Server Specifications

Operating in the Server mode, the module accepts commands from a Client(s) to read/write data stored in the module's internal registers. This data is easily and continuously transferred between the MVI module and the ControlLogix processor's data registers.

The IEC 60870-5-104 Server functionality supported by the module includes:

  • The IEC 60870-5-104 communication driver is built in accordance to the approved IEC specification
  • The module functions as a Server on the network supporting data read/write commands from an IEC 60870-5-104 client on the network
  • One TCP server socket
  • Supports unsolicited messages, either cyclic or spontaneous (cyclic rate is configurable)
  • Supports clock synchronization commands from client or from the ControlLogix
  • Supports Group interrogation (Global, General 1 to 16, Global Counters, Counters 1-4)
  • Event timestamping configurable by type (None, 24 bit, 56 bit)
  • Event queue supports 99 points for each data type
  • Optional user defined list of acceptable client host IP addresses
  • Configurable Common ASDU address (sector) and Information Object Address
  • An IEC Interoperability Document for the MVI56 is available which fully documents data types supported by the module.

Hardware Specifications

Ethernet and CFG Ports

 

Ethernet Port

RJ45 connection
10/100 Mbit Ethernet support (auto-sensing)
Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991
Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration

CFG Port

RJ45 (DB-9M with supplied cable)
RS-232 only

Shipped with unit

RJ45 to DB-9M adapter cable and 6-foot RS-232 configuration cable for debug port

Specification

Description

Backplane Current Load

800 mA @ 5 V

Operating Temperature

0 to 60°C (32 to 140°F)

Storage Temperature

-40 to 85°C (-40 to 185°F)

Shock:

30g Operational
50g non-operational
Vibration: 5 g from 10 to 150 Hz

Relative Humidity

5 to 95% (non-condensing)

LED Indicators:

Module Status
Backplane Transfer Status
Application Status
Serial Activity

Ordering Information

MVI56-104S IEC 60870-5-104 Server Communication Module
   
To place an order, please contact your local ProSoft Technology, Inc. distributor. For a list of ProSoft distributors near you, click here.

 

Distributors:
Place your order by email to orders@prosoft-technology.com:, fax to +1 661-716-5101.

Sales and Support:

Asia Pacific
+603.7724.2080
asiapc@prosoft-technology.com
Europe
+33 (0)5.34.36.87.20
europe@prosoft-technology.com
Latin America
Office: +1 281.298.9109
Mobile: +1-281-830-8946
latinam@prosoft-technology.com
North America
+1 661.716.5100
Fax: +1 661.716.5101
info@prosoft-technology.com

 

Related Information

ProSoft Configuration Builder

Home : Products : Support : Distributors : Services : News/Events : Contact Us : ProSoft Tested