'C' Programmable Application Development Module with Ethernet for CompactLogix
MVI69-ADMNET
The MVI69 'C' Programmable Application Development Module with Ethernet is a CompactLogix backplane compatible module that allows Rockwell Automation CompactLogix processors to interface with other Ethernet protocol compatible devices and hosts utilizing custom 'C'; code.
Features and Benefits
The ADMNET solution is a powerful module designed with both Client and Server support. This broad support enables the module to function as a data collection sub-master, or to be a powerful slave as a remote off an HMI host. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food processing.
The MVI69-ADMNET module is a single slot, backplane compatible solution for the Rockwell Automation CompactLogix platform. This module is a powerful and programmable solution supporting one fully isolated serial port, one non-isolated serial port, and one Ethernet port, allowing the many field devices to be integrated into the CompactLogix platform.
The MVI69-ADM module has two serial and one Ethernet port, one serial port is isolated for field interfaces.
- CFG -- debug/configuration -- RS-232
- PRT1 -- application -- RS-232, RS-422 or RS-485
- Ethernet port
Applications
The MVI69-ADMNET module is the ideal solution for many applications where Ethernet and serial connectivity must be added to a CompactLogix platform. Applications using the MVI69-ADMNET module include:
- Bar Code Scanner interface
- Legacy ASCII protocol connections
- Terminal Port Emulation
- Printer Driver (Alarm/Status printer)
- Customized protocol implementations
Functional Specifications
The MVI69-ADM API Suite allows software developers access to the top layer of the CompactLogix backplane and serial ports. The MVI69-ADMNET API suite accesses the Ethernet port.
Both APIs can be easily used without having detailed knowledge of the module's hardware design. The MVI69-ADMNET API Suite consists of the Ethernet Port API. The Ethernet Port API provides access to the Ethernet network. Applications for the MVI69-ADMNET module may be developed using industry-standard DOS programming tools and the appropriate API components.
The MVI69-ADMNET module has two serial ports, one of which is isolated for field interfaces, and one Ethernet port.
- CFG -- debug/configuration -- RS-232
- PRT1 -- Application -- RS-232, RS-422 or RS-485
- Ethernet Port
PRT1 is jumper configured for direct or Multidrop field communication. The application program can be written to control the two application ports independently, allowing maximum flexibility in the design.
General Protocol Specifications
- Allows software developers to access Rockwell Automation backplane and Serial/Ethernet ports without needing detailed knowledge of the module's hardware design
- API library functions are specified using the C programming language syntax
- The following compiler versions are compatible with the MVI module API:
- Digital Mars C++ 8.49
- Borland C++ V5.02
- Operating System - General software DOS 6-XL
- Flash ROM program space: 896 KB
- RAM program and data space: 640 KB
- Compact Flash socket: Up to 64 MB
ADM API Libraries
Each API provides a library of function calls. This library supports any programming language that is compatible with the Pascal calling convention.
- Initialization - Open and close the API
- Debug Port - Debug port user interface
- Database - Read and write data to database
- Timer - Start and check timers
- Backplane - Transfer data over the backplane
- LED - Set user LED indicators
- Flash - Parse configuration files
- Miscellaneous - Configure the console
Hardware Specifications
|
Dimensions
|
Standard 1769 Single-slot module
|
|
Current Load
|
800 mA max@ 5 VDC (Serial) Power supply distance rating of 2 (L43 and L45 installations on first 2 slots of 1769 bus)
|
|
Operating Temp.
|
0 to 60 Deg C
|
|
|
32 to 140 Deg F
|
|
Storage Temp.
|
-40 to 85 Deg C
|
|
|
-40 to 185 Deg F
|
|
Relative Humidity
|
5 to 95% (w/o condensation)
|
|
LED Indicators
|
Power and Module Status
|
|
|
Application Status
|
|
|
CFG Port Activity
|
|
|
Error Status
|
|
CFG Port
|
RJ45 (DB-9M w/ supplied cable)
|
|
|
RS-232 only
|
|
|
No hardware handshaking
|
|
App Port (Ethernet)
|
10/100 MB Ethernet compatible interface
Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration
Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991
|
|
Shipped with Unit
|
RJ45 to DB-9M cables for each port
|
|
|
6-foot RS-232 configuration Cable
|
Ordering Information
| MVI69-ADMNET |
'C' Programmable Application Development Module with Ethernet for CompactLogix |
| |
|
| To place an order, please contact your local ProSoft Technology, Inc. distributor. For a list of ProSoft distributors near you, click here. |
Distributors:
Place your order by email to orders@prosoft-technology.com:, fax to +1 661-716-5101.
Sales and Support:
|